QS_ALM_WF_VW(SQL View) |
Index Back |
---|---|
View for Alarm ReviewThis view uses QS_ALM_RVW_VW because it needs the exact structure the alarm review panel is based on. If that vw changes then this view also should be changed: Prasad Raju, 09/02/99 ======================================================== SELECT A.BUSINESS_UNIT , A.SESSN_ID , A.STREAM_ID , A.SESSN_SUBMIT_DTTM , A.SESSN_SGRP_SEQ , A.SESSN_SGRP_SIZE , A.QS_NVALUES , A.QS_VALUEREADING_1 , A.QS_VALUEREADING_2 , A.QS_VALUEREADING_3 , A.QS_VALUEREADING_4 , A.QS_VALUEREADING_5 , A.QS_VALUEREADING_6 , A.QS_VALUEREADING_7 , A.QS_VALUEREADING_8 , A.QS_VALUEREADING_9 , A.QS_VALUEREADING_10 , A.QS_VALUEREADING_11 , A.QS_VALUEREADING_12 , A.QS_VALUEREADING_13 , A.QS_VALUEREADING_14 , A.QS_VALUEREADING_15 , A.QS_VALUEREADING_16 , A.QS_VALUEREADING_17 , A.QS_VALUEREADING_18 , A.QS_VALUEREADING_19 , A.QS_VALUEREADING_20 , A.SPEC_VIO_SW , A.QS_ALARM_CNT , A.QS_ACTION_CNT , A.QS_CAUSE_CNT , A.QS_COMM_CNT , A.OPERATOR , C.MFDS_ID , D.QS_APP_CONTEXT , D.STREAM_ROOT_ID , D.INV_ITEM_ID , D.WORK_CENTER_CODE , D.MACHINE_CODE , D.STATION_CODE , D.CUST_ID , D.VENDOR_ID , D.TASK_CODE , D.PRDN_AREA_CODE , D.CREW_CODE , D.TOOL_CODE , D.COMPL_OP_SEQ , D.PRODUCTION_TYPE , D.QS_MFDS_PLAN_ID , D.DE_SETUP_NAME , D.QS_ATTRIB_SET_ID , E.MFDS_NAME , F.QS_MFDS_PLAN_NAME FROM PS_QS_SUBGROUP A , PS_QS_STREAM8 C , PS_QS_STREAM_ROOT D , PS_QS_MFDS_MST E , PS_QS_MFDS_PLAN F WHERE (A.QS_ALARM_CNT <> 0) AND (C.STREAM_ID = A.STREAM_ID AND D.STREAM_ROOT_ID = C.STREAM_ROOT_ID) AND (E.MFDS_ID = C.MFDS_ID) AND (F.QS_MFDS_PLAN_ID = D.QS_MFDS_PLAN_ID) |
SELECT A.BUSINESS_UNIT , A.SESSN_ID , A.STREAM_ID , D.QS_APP_CONTEXT , D.STREAM_ROOT_ID , A.SESSN_SUBMIT_DTTM , A.SESSN_SGRP_SEQ , A.SESSN_SGRP_SIZE , A.QS_NVALUES , A.QS_VALUEREADING_1 , A.QS_VALUEREADING_2 , A.QS_VALUEREADING_3 , A.QS_VALUEREADING_4 , A.QS_VALUEREADING_5 , A.QS_VALUEREADING_6 , A.QS_VALUEREADING_7 , A.QS_VALUEREADING_8 , A.QS_VALUEREADING_9 , A.QS_VALUEREADING_10 , A.QS_VALUEREADING_11 , A.QS_VALUEREADING_12 , A.QS_VALUEREADING_13 , A.QS_VALUEREADING_14 , A.QS_VALUEREADING_15 , A.QS_VALUEREADING_16 , A.QS_VALUEREADING_17 , A.QS_VALUEREADING_18 , A.QS_VALUEREADING_19 , A.QS_VALUEREADING_20 , A.SPEC_VIO_SW , A.QS_ALARM_CNT , A.QS_ACTION_CNT , A.QS_CAUSE_CNT , A.QS_COMM_CNT , A.OPERATOR , C.MFDS_ID , %subrec(QS_HIER_SBR, D) , D.QS_MFDS_PLAN_ID , D.DE_SETUP_NAME , D.QS_ATTRIB_SET_ID , E.MFDS_NAME , F.QS_MFDS_PLAN_NAME FROM PS_QS_SUBGROUP A , PS_QS_STREAM8 C , PS_QS_STREAM_ROOT D , PS_QS_MFDS_MST E , PS_QS_MFDS_PLAN F WHERE (A.QS_ALARM_CNT <> 0 AND A.DISPATCH_FLAG = 'N') AND (C.STREAM_ID = A.STREAM_ID AND D.STREAM_ROOT_ID = C.STREAM_ROOT_ID) AND (E.MFDS_ID = C.MFDS_ID) AND (F.QS_MFDS_PLAN_ID = D.QS_MFDS_PLAN_ID) |
# | PeopleSoft Field Name | PeopleSoft Field Type | Database Column Type | Description |
---|---|---|---|---|
1 | BUSINESS_UNIT | Character(5) | VARCHAR2(5) NOT NULL |
Business Unit
Prompt Table: SP_BUQS_NONVW |
2 | SESSN_ID | Character(30) | VARCHAR2(30) NOT NULL | Session ID |
3 | STREAM_ID | Number(8,0) | INTEGER NOT NULL | Stream ID- hierarchial structure plus characteristic. (or Stream Root ID plus characteristic). |
4 | QS_APP_CONTEXT | Character(18) | VARCHAR2(18) NOT NULL | QC application context identifier |
5 | STREAM_ROOT_ID | Number(8,0) | INTEGER NOT NULL | Stream Root ID - hierarchal structure |
6 | SESSN_SUBMIT_DTTM | DateTime(26) | TIMESTAMP | Date Submitted |
7 | SESSN_SGRP_SEQ | Number(6,0) | INTEGER NOT NULL | Subgroup ID |
8 | SESSN_SGRP_SIZE | Number(13,5) | DECIMAL(12,5) NOT NULL | Subgroup Size |
9 | QS_NVALUES | Number(3,0) | SMALLINT NOT NULL | number of values |
10 | QS_VALUEREADING_1 | Signed Number(15,6) | DECIMAL(13,6) NOT NULL | Value |
11 | QS_VALUEREADING_2 | Signed Number(15,6) | DECIMAL(13,6) NOT NULL | Value |
12 | QS_VALUEREADING_3 | Signed Number(15,6) | DECIMAL(13,6) NOT NULL | Value |
13 | QS_VALUEREADING_4 | Signed Number(15,6) | DECIMAL(13,6) NOT NULL | Value |
14 | QS_VALUEREADING_5 | Signed Number(15,6) | DECIMAL(13,6) NOT NULL | Value |
15 | QS_VALUEREADING_6 | Signed Number(15,6) | DECIMAL(13,6) NOT NULL | Value |
16 | QS_VALUEREADING_7 | Signed Number(15,6) | DECIMAL(13,6) NOT NULL | Value |
17 | QS_VALUEREADING_8 | Signed Number(15,6) | DECIMAL(13,6) NOT NULL | Value |
18 | QS_VALUEREADING_9 | Signed Number(15,6) | DECIMAL(13,6) NOT NULL | Value |
19 | QS_VALUEREADING_10 | Signed Number(15,6) | DECIMAL(13,6) NOT NULL | Value |
20 | QS_VALUEREADING_11 | Signed Number(15,6) | DECIMAL(13,6) NOT NULL | Value |
21 | QS_VALUEREADING_12 | Signed Number(15,6) | DECIMAL(13,6) NOT NULL | Value |
22 | QS_VALUEREADING_13 | Signed Number(15,6) | DECIMAL(13,6) NOT NULL | Value |
23 | QS_VALUEREADING_14 | Signed Number(15,6) | DECIMAL(13,6) NOT NULL | Value |
24 | QS_VALUEREADING_15 | Signed Number(15,6) | DECIMAL(13,6) NOT NULL | Value |
25 | QS_VALUEREADING_16 | Signed Number(15,6) | DECIMAL(13,6) NOT NULL | Value |
26 | QS_VALUEREADING_17 | Signed Number(15,6) | DECIMAL(13,6) NOT NULL | Value |
27 | QS_VALUEREADING_18 | Signed Number(15,6) | DECIMAL(13,6) NOT NULL | Value |
28 | QS_VALUEREADING_19 | Signed Number(15,6) | DECIMAL(13,6) NOT NULL | Value |
29 | QS_VALUEREADING_20 | Signed Number(15,6) | DECIMAL(13,6) NOT NULL | Value |
30 | SPEC_VIO_SW | Character(1) | VARCHAR2(1) NOT NULL | Spec Violation |
31 | QS_ALARM_CNT | Signed Number(4,0) | DECIMAL(3) NOT NULL | # control test violations occuring for a single subgroup |
32 | QS_ACTION_CNT | Number(3,0) | SMALLINT NOT NULL | Corrective Actions |
33 | QS_CAUSE_CNT | Number(3,0) | SMALLINT NOT NULL | Pobable Causes |
34 | QS_COMM_CNT | Number(2,0) | SMALLINT NOT NULL | Comments |
35 | OPERATOR | Character(30) | VARCHAR2(30) NOT NULL | User ID |
36 | MFDS_ID | Number(6,0) | INTEGER NOT NULL | ID of the Characteristic. |
37 | INV_ITEM_ID | Character(18) | VARCHAR2(18) NOT NULL | Item ID |
38 | WORK_CENTER_CODE | Character(10) | VARCHAR2(10) NOT NULL | Work Center |
39 | MACHINE_CODE | Character(10) | VARCHAR2(10) NOT NULL | Machine Code |
40 | STATION_CODE | Character(10) | VARCHAR2(10) NOT NULL | Station Code |
41 | CUST_ID | Character(15) | VARCHAR2(15) NOT NULL | Uniquely identifies an organizational entity that purchases goods or services from the enterprise. Represents the sold-to customer which is the customer organization that places orders. The CUST_ID may or may not be the same as the identifiers for the bill-to and ship-to locations. |
42 | VENDOR_ID | Character(10) | VARCHAR2(10) NOT NULL | Vendor Identifier |
43 | TASK_CODE | Character(6) | VARCHAR2(6) NOT NULL | Task Code |
44 | PRDN_AREA_CODE | Character(10) | VARCHAR2(10) NOT NULL | Production Area |
45 | CREW_CODE | Character(10) | VARCHAR2(10) NOT NULL | Crew Name |
46 | TOOL_CODE | Character(10) | VARCHAR2(10) NOT NULL | Tool ID |
47 | COMPL_OP_SEQ | Number(4,0) | SMALLINT NOT NULL | Completion Operation Sequence |
48 | PRODUCTION_TYPE | Character(2) | VARCHAR2(2) NOT NULL |
JNW 11/1/98 (CN#SF800-13) activated teardown xlat
PR=Production RW=Rework SV=Service TD=Teardown |
49 | QC_STEP_ID | Character(18) | VARCHAR2(18) NOT NULL | QC Step Id |
50 | QS_MFDS_PLAN_ID | Number(8,0) | INTEGER NOT NULL | ADDED label field name for display purposes |
51 | DE_SETUP_NAME | Character(48) | VARCHAR2(48) NOT NULL | Inspection setup name |
52 | QS_ATTRIB_SET_ID | Number(5,0) | INTEGER NOT NULL | Attribute set ident |
53 | MFDS_NAME | Character(30) | VARCHAR2(30) NOT NULL | Characteristic |
54 | QS_MFDS_PLAN_NAME | Character(38) | VARCHAR2(38) NOT NULL | Measurement plan identifier Note: replaces qc_step_id for release 8. |