WM_INCLC_CP_VW(SQL View) |
Index Back |
---|---|
Inspection Calc Parm View |
SELECT A.SETID , A.INSPECTION_CODE AS CALCLT_PARM_CODE , '1' , A.INSP_MEASMT_TYPE AS INSP_CODE_SUBTYPE , A1.XLATLONGNAME AS INSP_CD_SUBTYP_LBL , A.DESCR50 , A.EFF_STATUS , A.MEASMT_DEVICE_TYPE , A.BASE_UOM , A.ASSET_TYPE , A.ASSET_SUBTYPE , A.MFG_ID , A.MODEL FROM PS_WM_INSP_MMT_HDR A , PS_WM_INSP_CDSB_VW A1 WHERE A1.INSP_CODE_TYPE = '1' AND A1.INSP_CODE_SUBTYPE = A.INSP_MEASMT_TYPE UNION SELECT B.SETID , B.INSPECTION_CODE AS CALCLT_PARM_CODE , '2' , B.INSP_OBSRVN_TYPE AS INSP_CODE_SUBTYPE , B1.XLATLONGNAME AS INSP_CD_SUBTYP_LBL , B.DESCR50 , B.EFF_STATUS , ' ' , ' ' , B.ASSET_TYPE , B.ASSET_SUBTYPE , B.MFG_ID , B.MODEL FROM PS_WM_INSP_OBS_HDR B , PS_WM_INSP_CDSB_VW B1 WHERE B1.INSP_CODE_TYPE = '2' AND B1.INSP_CODE_SUBTYPE = B.INSP_OBSRVN_TYPE UNION SELECT C.SETID , C.INSPECTION_CODE AS CALCLT_PARM_CODE , '3' , C.INSP_CALCLT_TYPE AS INSP_CODE_SUBTYPE , C1.XLATLONGNAME AS INSP_CD_SUBTYP_LBL , C.DESCR50 , C.EFF_STATUS , ' ' , C.BASE_UOM , C.ASSET_TYPE , C.ASSET_SUBTYPE , C.MFG_ID , C.MODEL FROM PS_WM_INSP_CLC_HDR C , PS_WM_INSP_CDSB_VW C1 WHERE C.INSP_CALCLT_TYPE = '10' AND C1.INSP_CODE_TYPE = '3' AND C1.INSP_CODE_SUBTYPE = C.INSP_CALCLT_TYPE |
# | PeopleSoft Field Name | PeopleSoft Field Type | Database Column Type | Description |
---|---|---|---|---|
1 | SETID | Character(5) | VARCHAR2(5) NOT NULL |
SetID
Default Value: OPR_DEF_TBL_FS.SETID Prompt Table: SP_SETID_NONVW |
2 | CALCLT_PARM_CODE | Character(20) | VARCHAR2(20) NOT NULL | Inspection Code |
3 | INSP_CODE_TYPE | Character(1) | VARCHAR2(1) NOT NULL |
Inspection Code Type
1=Measurement 2=Observation 3=Calculation |
4 | INSP_CODE_SUBTYPE | Character(2) | VARCHAR2(2) NOT NULL |
Inspection Code Subtype
Prompt Table: WM_INSP_CDSB_VW |
5 | INSP_CD_SUBTYP_LBL | Character(30) | VARCHAR2(30) NOT NULL | Inspection Code Subtype |
6 | DESCR50 | Character(50) | VARCHAR2(50) NOT NULL | Description of length 50 |
7 | EFF_STATUS | Character(1) | VARCHAR2(1) NOT NULL |
Effective Status
A=Active I=Inactive |
8 | MEASMT_DEVICE_TYPE | Character(30) | VARCHAR2(30) NOT NULL | Measurement Device Type |
9 | BASE_UOM | Character(3) | VARCHAR2(3) NOT NULL |
Base Unit of Measure
Prompt Table: UNITS_TBL |
10 | ASSET_TYPE | Character(3) | VARCHAR2(3) NOT NULL |
Asset Type
010=IT Hardware 020=IT Software 040=Equipment 050=Property 060=Fleet 070=Machinery 080=Furniture 090=Facility 100=Intangible 200=Asset Retirement Obligations 999=Other |
11 | ASSET_SUBTYPE | Character(15) | VARCHAR2(15) NOT NULL |
Asset Subtype
Prompt Table: AM_SUBTYPE |
12 | MFG_ID | Character(50) | VARCHAR2(50) NOT NULL |
Manufacturer ID
Prompt Table: WM_MANUFACTURER |
13 | MODEL | Character(30) | VARCHAR2(30) NOT NULL |
Model